콘텐츠로 건너뛰기

E²T Pulsar Sulfur Recovery Unit Pyrometer

Active

Infrared Thermometry for Sulfur Reactors and High Temperature Furnaces

The E2T PulsarTM 4 Advanced measures two wavelengths for continuous and instantaneous measurement of refractory temperature (RT), gas temperature (GT) and integrated temperature (FF), reporting both readings simultaneously in one instrument. The E2T PulsarTM 4 is a single channel option for direct replacement of older Pulsar II models. The innovative Advanced Energy Smart FMA Flame Measurement Algorithm allows for accurate real-time flame transparency compensation and correction. Applying the flame transparency calculation with FMA removes the flame transparency errors due to the gas (flame) temperature, providing the highest accuracy in process temperatures.

특징

  • Explosion-proof certification
    • IECEx, ATEX II 2G EXd IIB+H2 T4,
    • FM (US and CSA) Class I, Div I, Group B, C & D, T4
    • regional certification like UKEx, KOSA, CCOE, INMETRO or TP/TC
  • Integrated power supply, capable of operating with 24 VDC /120/230 VAC
  • HART Rev 7 protocol (Advanced version only) and RS485 interface
  • SmartFMA for highest GT and RT measurment

혜택

  • Prevent damage to the furnace refractory with high temperature alarms
  • Install a single system with two independent infrared filtered detectors for gas (GT) and refractory (RT) measurements
  • Quickly react to control the furnace process temperatures with instant readings
  • Gain higher operational safety with accurate refractory measurement and high temperature alarms
  • Use Smart FMA to remove flame transparency errors that typical pyrometers experience (Advanced version only)

사양

작동 온도 범위(°C): 350 to 2000
측정 불확도(°C): 3°C + 1 digit
주변 온도(°C): -40 to 60
초점 범위(mm/mtr): 500 to Infinity
전 등급: IECEx db +H2 IIB T4
인클로저 재질: 316L stainless steel

기술 문서

기술 동영상

24시간 (24/5) 고객 지원

전문 엔지니어의 기술지원을 받아보세요.

저희는 고객에게 우수한 고객 서비스와 기술 지원을 제공하기 위해 최선을 다하고 있습니다. 실시간 채팅 및 전화 지원을 통해 언제든지 자격을 갖춘 엔지니어에게 도움을 요청할 수 있습니다.
지금 지원 받기