コンテンツへスキップ

E²T Pulsar Sulfur Recovery Unit Pyrometer

Active

Infrared Thermometry for Sulfur Reactors and High Temperature Furnaces

The E2T PulsarTM 4 Advanced measures two wavelengths for continuous and instantaneous measurement of refractory temperature (RT), gas temperature (GT) and integrated temperature (FF), reporting both readings simultaneously in one instrument. The E2T PulsarTM 4 is a single channel option for direct replacement of older Pulsar II models. The innovative Advanced Energy Smart FMA Flame Measurement Algorithm allows for accurate real-time flame transparency compensation and correction. Applying the flame transparency calculation with FMA removes the flame transparency errors due to the gas (flame) temperature, providing the highest accuracy in process temperatures.

特徴

  • Explosion-proof certification
    • IECEx, ATEX II 2G EXd IIB+H2 T4,
    • FM (US and CSA) Class I, Div I, Group B, C & D, T4
    • regional certification like UKEx, KOSA, CCOE, INMETRO or TP/TC
  • Integrated power supply, capable of operating with 24 VDC /120/230 VAC
  • HART Rev 7 protocol (Advanced version only) and RS485 interface
  • SmartFMA for highest GT and RT measurment

メリット

  • Prevent damage to the furnace refractory with high temperature alarms
  • Install a single system with two independent infrared filtered detectors for gas (GT) and refractory (RT) measurements
  • Quickly react to control the furnace process temperatures with instant readings
  • Gain higher operational safety with accurate refractory measurement and high temperature alarms
  • Use Smart FMA to remove flame transparency errors that typical pyrometers experience (Advanced version only)

仕様

動作温度範囲 (°C): 350 to 2000
測定の不確かさ (°C): 3°C + 1 digit
周囲温度 (°C): -40 to 60
フォーカス範囲(mm/mtr): 500 to Infinity
元レーティング: IECEx db +H2 IIB T4
エンクロージャー素材: 316L stainless steel

技術文書

テクニカル・ビデオ

24/5サポートをご利用下さい

エンジニアによる専門的なアドバイス

当社は、お客様に優れたカスタマーサービスとテクニカルサポートを提供することをお約束します。ライブチャットと電話サポートで、適任のエンジニアにいつでもご相談いただけます。
今すぐサポートを受ける