Temperature Measurement Products

Impac IN 2000 and IN 3000

Stationary Infrared Sensors for Non-Contact Temperature Measurement of Non-Metallic Surfaces, -32 to 500°C

Advanced Energy’s stationary Impac IN 2000 and IN 3000 pyrometers offer excellent value and are ideal for non-metallic surfaces and painted, coated, or anodized metals.

  • Compact
  • Built-in air purge unit
  • Stainless steel housing with PG 11 thread
  • Up to 70°C operating temperature with no need for cooling
  • Easy installation
  • Overview
  • Technical Specs
  • Documents
  • Accessories
  • Service & Support

Overview

The compact Impac® IN 2000 and IN 3000 stationary infrared sensors are ideal for non-contact temperature measurement of non-metallic surfaces as well as painted, coated, and anodized metals. Their solid and robust design allows for use in rough industrial environments. They each have a built-in air purge to protect their lenses from dust and moisture contamination, which allows the devices to adapt to various measuring tasks.

The IN 3000 is an analog measuring device with three different outputs. The IN 2000 is a digital pyrometer equipped with an interface output for USB connection. You can adjustment all IN 2000 parameters via PC.

Benefits

  • Use in small spaces
  • Easily mount
  • Keep the lens clean in dusty environments via the air-purge unit
  • Adapt to various measuring tasks
  • Easily install and connect

Features

  • Solid and robust design
  • Up to 70°C operating temperature with no need for cooling
  • IN 3000: Analog device with three outputs
  • IN 2000: Digital pyrometer with USB connectivity
  • Built-in air purge

Select specifications are shown below. Please see product data sheet for additional specifications.

  • Temperature Ranges

    IN 2000

    -32 to 900°C (-25.6 to 1652°F)

    IN 3000

    0 to 120°C (32 to 248°F)
    0 to 300°C (32 to 572°F)
    100 to 500°C (212 to 932°F)

  • Measurement

    Spectral Range

    8 to 14 μm

    Measurement Uncertainty

    Repeatability

    IN 2000: < 0.3% of measured value (ε=1)
    IN 3000: 1% of measured value or 1°C (whichever is greater)

    Exposure Time t90

    IN 2000: 95 ms (adjustable to 0.5 up to 120 s)
    IN 3000: 300 ms

    Emissivity ε

    IN 2000: 10.0 to 100.0% (adjustable via interface)
    IN 3000: 95% (fixed)

    Transmittance τ

    10.0 to 100.0% (adjustable via interface)

  • Optical

    Sighting

    None

    Optics

    One fixed optics: a = 50 mm

    Distance Ratio (FOV)

    10:1 (min. 5 mm)

  • Interface and Communication

    Parameters

    Temperature display in °C or °F, emissivity ε, exposure time t90, settings of the max / minimum value storage, temperature subrange, ambient temperature compensation, adresse, baud rate

    Analog Output

    IN 2000: 4 to 20 mA
    IN 3000: 10 mV/°C or thermocouple type J or K

    Digital Output

    Output for connecting a USB adapter (only IN 2000)

  • Environmental

    Protection Class

    IP 65 (DIN 40050)

    Operating Position

    Any

    Ambient Temperature

    0 to 70°C (32 to 158°F) at housing

    Storage Temperature

    -20 to 70°C (-4 to 158°F)

    Relative Humidity

    Non-condensing conditions

    Weight

    0.150 kg (~0.331 lb)

    Housing

    Stainless steel

    CE Label

    According to EU directives about electromagnetical immunity

  • Electrical

    Power Supply

    IN 2000: 15 to 30 VDC
    IN 3000: 18 to 30 VDC

    Load

    IN 2000: Maximum 375 Ω at 15 V up to maximum 1125 Ω at 30 V
    IN 3000: Minimum 50 kΩ

  • Typical Applications

    • Plastics
    • Textiles
    • Asphalt
    • Rubber
    • Paint
    • Glass
    • Wood
    • Varnish
    • Ceramic
    • Paper
    • Liquids
    • Food
    • Painted metals
    • Coated metals
    • Anodized metals

Specifications are subject to change without notice. Not all options and accessories are available for all models and configurations. Dimensions listed generally refer to standard configurations and module bodies only. Please confirm technical specifications and customizations with a sales representative. Advanced Energy is not responsible for errors or omissions.

Accessories

Power Supplies

Fast, Digital, and Programmable PID Controller

PI 6000 Controller

Extremely Fast, Digital, and Programmable PID Controller

MultiTempLogger

Multi-Channel Measuring Data Logging Software

InfraWin

Pyrometer Measurement and Evaluation Software

Global Support & Services

Maximize fab productivity and capital equipment ROI with world-class support through each product lifecycle stage — from startup to long-term operation. Our service offerings are based on more than three decades of precision power and applications expertise.

Learn More

Applications Support & Consulting

Accelerate tool installations and process development programs, or address specific applications concerns with Advanced Energy's dedicated applications consultants and engineering staff. Benefit from on-site reviews, analyses, and consultations.

Learn More

Warranties

Decrease variability in maintenance costs and provide additional cost protection. Advanced Energy offers whole-box extended warranties.

Learn More

Product Support

Call
Inside the U.S.: 1.800.446.9167 (option 2)
Outside the U.S.


Email
Thin Film Support
Thermal Product Support
Other Technical Support

Thank You

You may now view any resource on the Advanced Energy site. Click the button below to view your requested resource.

Thank You

You may now view any resource on the Advanced Energy site. Click the button below to view your requested resource.