High Voltage Power Supplies

IP100 Series

Single-Output, 115 W High Voltage, Vacuum Chamber Power Supply

The IP100 Series includes a range of high voltage power supplies designed to drive a vacuum chamber ion pump where a vacuum in the region of 1E-11 Torr is required.

  • Max Output Voltage: 7 kV
  • Max Output Power: 115 W output at 240 V input
  • Ripple: < 4286 ppm (30 Vpp)
  • Control Interface: Analog
  • Overview
  • Technical Specs
  • Service & Support

Overview

Advanced Energy’s IP100 Series features a suite of power supplies designed to drive a vacuum chamber ion pump. The IP100 Series is also suitable for use in mass spectrometers, scanning electron microscopes, and high-integrity vacuum systems. Lightweight and compact, IP100 Series supplies meet small-footprint application requirements. And their robust design ensures that the power supply is immune to output short-circuit.

Benefits

  • Incorporate an air insulated HV assembly to achieve a total weight of less than 1.6 kg (3.5 lb)
  • Ensure the power supply is immune to output short circuit via a robust design
  • Disable power supply using safety interlock feature
  • Enable pressure measurement with a wide-range current monitor

Features

  • Compact size
  • Lightweight – only 1.6 kg
  • EU Directive 2002/95/EC compliant
  • Electrical

    Output Voltage

    5 kV or 7 kV

    Max Output Power

    115 W

    Ripple

    < 4286 ppm (< 30 Vpp) 

    Temperature Coefficient

    N/A

    Input Voltage

    90 to 265 VAC, 47 to 63 Hz single-phase, plus protective earth

    Input Current

    2 A max  

  • Environmental

    Operating Temperature Range

    10 to 40°C (32 to 140°F)

    Humidity

    80% max relative humidity up to 31°C (88°F)

  • Mechanical

    Dimensions

    160 x 277 x 112 mm3 (6.3 x 10.9 x 4.41 in3) (W x D x H)

    Weight

    1.6 kg (3.5 lb) 

  • Interface

    Option Available

    Analog 9-way D-type connector

Specifications are subject to change without notice. Not all options and accessories are available for all models and configurations. Dimensions listed generally refer to standard configurations and module bodies only. Please confirm technical specifications and customizations with a sales representative. Advanced Energy is not responsible for errors or omissions.

Global Support & Services

Maximize fab productivity and capital equipment ROI with world-class support through each product lifecycle stage — from startup to long-term operation. Our service offerings are based on more than three decades of precision power and applications expertise.

Learn More

Applications Support & Consulting

Accelerate tool installations and process development programs, or address specific applications concerns with Advanced Energy's dedicated applications consultants and engineering staff. Benefit from on-site reviews, analyses, and consultations.

Learn More

Warranties

Decrease variability in maintenance costs and provide additional cost protection. Advanced Energy offers whole-box extended warranties.

Learn More

Product Support

Call
Inside the U.S.: 1.800.446.9167 (option 2)
Outside the U.S.


Email
Thin Film Support
Thermal Product Support
Other Technical Support

Compare Products

Model

IP100

Classification

Vacuum chamber power supply

35 kV SEM power supply

60 kV E-Beam power supply

Maximum Output Power

115 W

Accelerator: 6 W
Extractor: 4 W
Suppressor: 0.1 W
Heater: 15 W

Accelerator: 6 W
Extractor: 4 W
Suppressor: 0.2 W
Focus: 0.75 W
Heater: 15 W

Maximum Output Voltage

7 kV

Accelerator: -30 kV, 200 µA (-35 kV for conditioning)
Extractor: +10 kV, 400 µA
Suppressor: -1 kV, 100 µA
Heater: +5 V, 3 A

Accelerator: -60 kV, 100 µA
Extractor: +10 kV, 400 µA
Suppressor: -1 kV, 20 µA
Focus: +25 kV, 30 µA
Heater: +5 V, 3 A

Type

Single Output

Single Output (non-reversing)

Single Output (non-reversing)

Ripple (Best Performance)

< 4286 ppm (< 30 Vpp)

Accelerator: < 2 ppm (50 mVpp)
Extractor: < 2 ppm (20 mVpp)
Suppressor: < 30 ppm (30 mVpp)
Heater: LF < 1 mA pp, HF < 5 mVpp with a 1 Ω load

Accelerator: < 2 ppm (75 mVpp)
Extractor: < 4 ppm (35 mVpp)
Suppressor: < 25 ppm (25 mVpp)
Focus: < 4 ppm (100 mV)
Heater: LF < 1 mApp, HF < 5 mVpp with a 1 Ω load

Volume (Smallest Model)

4964 cm3 (0.175 ft3)

0.010 m3 (0.366 ft3)

0.042 m3 (1.48 ft3)